AS 2047:2014 is the Australian Standard that governs how windows and external glazed doors must be designed, tested, constructed and installed in buildings. Before you order a single unit, request the supplier’s AS 2047 test certificate and confirm the label matches your specified design wind pressure. The National Construction Code (NCC) references AS 2047 directly, so compliance is not optional on any regulated building project. Hansaluminium supplies custom aluminium windows with full AS 2047 certification support across residential, commercial and industrial projects.
Key procurement actions before ordering:
- Request the AS 2047 test certificate showing tested sizes and design wind pressures.
- Confirm the product label matches the tested configuration.
- Cross-check the NCC edition applicable to your building class.
- Verify the supplier’s factory quality system documentation.
Key takeaways
AS 2047:2014 is the mandatory Australian Standard for external windows and glazed doors, and NCC Part 8.2 makes correct installation a compliance requirement alongside product testing.
| Point | Details |
|---|---|
| Request certificates first | Ask for AS 2047 test certificates showing tested sizes and design wind pressures before ordering any unit. |
| Specify ratings on drawings | Nominate the design wind pressure or classification (N or C class) derived from your site wind speed assessment. |
| Fix packers permanently | Packers must be compatible with the frame material, placed at fixing points, and fixed so the assembly stays straight over time. |
| Isolate aluminium from masonry | Apply a bituminous membrane or compatible coating at every aluminium-to-masonry contact point to prevent corrosion and water ingress. |
| Hansaluminium for compliance support | Hansaluminium supplies labelled, AS 2047-certified custom aluminium windows with test certificate documentation and NCC Part 8.2-aligned installation guidance. |
Table of Contents
- What does AS 2047 actually cover, and what does it exclude?
- What are the core performance requirements and rating system?
- How to get installation right on site
- What labelling and certificates should you require?
- How to specify AS 2047-compliant windows on drawings and documents
- Common pitfalls and on-site quality-control checks
- How AS 2047 compliance affects energy efficiency and thermal performance
- How do AS 2047 requirements change across climatic zones?
- AS 2047 amendment history and how to stay current
- What fabricators need from design teams early
- Hansaluminium: AS 2047-compliant aluminium windows for your project
- Sources
What does AS 2047 actually cover, and what does it exclude?
AS 2047:2014 prescribes requirements for materials, testing, construction, installation and labelling across external windows, sliding and swinging glazed doors, shopfronts, window walls and one-piece framing elements. If it sits in an external wall and contains glazing, AS 2047 almost certainly applies.
Several categories fall outside the standard’s scope:
- Internal doors and partitions
- Skylights, rooflights and windows not in the vertical plane
- Greenhouse windows and horticultural glazing
- Frameless sliding doors
- Site-constructed or heritage windows (subject to specific NCC provisions)
Industry guidance from AGWA confirms that all windows and glazed doors in an external wall must be tested to AS 2047, with limited exceptions for non-vertical windows or heritage items. When you are unsure whether a product falls within scope, check the NCC volume applicable to your building class and confirm with your certifier before procurement.
What are the core performance requirements and rating system?
AS 2047 assesses window assemblies across six performance axes. Understanding each one helps you specify correctly and interpret a supplier’s test report with confidence.

Glazing within the assembly must comply with AS 1288, which governs glass selection and thickness for buildings. AS 5203 covers acoustic performance where that is a project requirement. Ratings for housing are typically expressed as a design wind pressure class (for example, N1 through N6 for non-cyclonic zones, C1 through C4 for cyclonic zones). Higher building classes require a tested design wind pressure in kilopascals matched to the site wind speed from AS/NZS 1170.2.
Pro Tip: When reviewing a supplier’s test report, check that the tested unit size is equal to or larger than the unit you are ordering. A certificate for a smaller assembly does not validate a larger one.
How to get installation right on site
The NCC’s 2022 edition introduced explicit installation guidance in Part 8.2 that makes correct on-site practice a compliance requirement, not just good workmanship. Incorrect packing or failure to isolate aluminium from masonry leads to corrosion, water ingress and early failure even when products are tested to AS 2047.
- Place packers along each side and the bottom. Packers must be located at fixing points and must not obstruct flashing or drainage paths.
- Fix packers permanently. Temporary packers left in place are a common defect. Use materials compatible with aluminium and the surrounding substrate.
- Square the assembly before fixing. Check that diagonals are equal and the frame is perpendicular. Diagonal distortion causes sash binding, seal failure and water ingress.
- Leave a top gap for settlement. Transfer design wind loads only to the framing members beside the window, never through the head of the frame to the structure above.
- Isolate aluminium from masonry. Apply a bituminous membrane or compatible coating at every contact point between the aluminium sill and masonry to prevent galvanic corrosion.
- Seal and flash correctly. Flashings must direct water away from the frame. Confirm drainage paths are clear before sealing the perimeter.
Pro Tip: Aluminium sills in direct contact with concrete or masonry are one of the most frequent remedial items on site. Detail the isolation layer on your drawings before construction starts, not after.
What labelling and certificates should you require?
Every AS 2047-compliant window assembly must carry a label or certificate that documents its tested configuration and applicable limits. Section 8 of AS 2047 sets out what that label must contain. When you receive a compliance pack from a supplier, confirm it includes:
- The AS 2047:2014 designation and the edition or amendment number.
- The tested unit size (width and height) and the maximum permissible size.
- The design wind pressure or classification achieved.
- The test methods used (AS 4420 series references).
- The name of the accredited testing laboratory.
- Evidence of factory quality assurance, such as a documented QA system or third-party audit.
The NCC references AS 2047 in both Volume One (commercial buildings) and Volume Two (housing provisions, Part 8.2). A certifier reviewing your compliance pack will check that the label or certificate matches the unit installed on site. Requesting labelled test certificates that show the exact tested size and configuration prevents mismatches between laboratory results and site assemblies. Standards Australia is the authoritative source for the standard’s formal designation and purchase.
How to specify AS 2047-compliant windows on drawings and documents
Clear specification language removes ambiguity and protects you if a dispute arises. Use this structure on drawings and in procurement schedules:
- Reference the standard. State “AS 2047:2014 — Windows and external glazed doors in buildings” on every window schedule.
- Nominate the required rating. Specify the design wind pressure in kilopascals or the classification (for example, N3 or C2) derived from your site wind speed assessment.
- Specify glazing compliance. Note “Glazing to AS 1288” alongside the glass type, thickness and any safety or acoustic requirements.
- Require factory labelling. Add “Units to be supplied with AS 2047 label or certificate prior to delivery” to your procurement conditions.
- Request the test matrix. Ask for a scope or matrix showing which tested configurations cover the sizes on your schedule.
- Confirm installer competence. Require evidence that the installing contractor is familiar with NCC Part 8.2 installation requirements.
Pro Tip: Avoid specifying only “to Australian Standards” without nominating the standard number and required rating. Vague wording gives a supplier room to supply a product tested to a lower wind pressure than your site demands.
Common pitfalls and on-site quality-control checks
Recurring defects on AS 2047 projects fall into a predictable pattern. Knowing them in advance lets you catch problems before they become costly remedial work.
Frequent issues to watch for:
- Mis-sized assemblies delivered against an incorrect opening dimension.
- Packer materials incompatible with the frame (for example, timber packers in wet areas).
- Packers not fixed permanently, allowing the frame to shift after installation.
- Inadequate isolation between aluminium and masonry, leading to corrosion.
- Flashings installed incorrectly or omitted at the head.
- Drainage paths blocked by sealant or debris.
- Fixing points transferring load to the head rather than the jamb framing.
On-site inspection checklist before sign-off:
- Confirm unit label or certificate is present and matches the installed size.
- Check squareness: measure both diagonals and confirm they are equal.
- Verify top gap is present and not bridged by sealant or packing.
- Inspect packer placement: sides and bottom, fixed, clear of flashing.
- Confirm aluminium-to-masonry isolation is visible at the sill.
- Check flashings are lapped correctly and drainage paths are unobstructed.
- Test operating force: sashes must open, close and latch without excessive effort.
If any of these items fail, do not sign off the installation. Request remedial work and re-inspect before proceeding to the next trade.
How AS 2047 compliance affects energy efficiency and thermal performance
AS 2047 sets the structural and weathertightness baseline for window assemblies, but energy efficiency sits in an adjacent layer of requirements. The NCC’s energy provisions (Section J for commercial buildings, the Nationwide House Energy Rating Scheme for housing) require windows to meet minimum thermal performance targets expressed as U-values and Solar Heat Gain Coefficients (SHGC). An AS 2047-compliant window is not automatically energy-efficient; it simply meets the structural and weathertightness floor.
Where the two standards connect is at the glazing specification. AS 1288, referenced within AS 2047, governs glass selection. Choosing thermally broken aluminium frames, double-glazed units or low-emissivity coatings improves U-values and SHGC without affecting AS 2047 compliance. Specifying awning windows with compression seals, for example, delivers better air infiltration results than sliding configurations, which directly supports both AS 2047 air infiltration performance and NCC energy targets.

How do AS 2047 requirements change across climatic zones?
The standard itself does not prescribe different performance levels by climate zone. Instead, the design wind pressure your windows must achieve is determined by the site wind speed classification under AS/NZS 1170.2, which varies by location and terrain category. Coastal and cyclonic regions in northern and north-western Australia require C-class ratings (C1 through C4), while most southern and inland areas require N-class ratings (N1 through N6).
Beyond wind, exposure conditions affect material durability requirements. Buildings within one kilometre of breaking surf or in industrial environments with airborne pollutants require corrosion-resistant finishes and seals. Specifiers in these zones should confirm that the supplier’s tested configuration includes the appropriate finish and that the test certificate covers the exposure category relevant to the site.
AS 2047 amendment history and how to stay current
The current edition is AS 2047:2014, which superseded the 1999 edition. Amendment 2 (referenced as DR AS 2047-2014 Amd 2) has been issued since the original publication. The NCC 2022 edition introduced new explicit installation guidance in Part 8.2, which works alongside AS 2047 rather than replacing it.
To stay current, subscribe to Standards Australia’s update notifications for AS 2047 and its companion standards (AS 4420 series, AS 1288, AS 5203). When a new NCC edition is adopted by your state or territory, check whether the referenced edition of AS 2047 has changed, as NCC adoption timelines vary across jurisdictions.
What fabricators need from design teams early
Compliance problems on site almost always trace back to decisions made, or not made, at the design stage. From a fabricator’s perspective, the information that matters most arrives too late on too many projects.
Custom aluminium window profiles require lead time for extrusion and finishing. If a project’s wind pressure rating is not confirmed until after the shop drawings are submitted, the fabricator may need to revise the profile, retest, or substitute a heavier section, all of which compress the programme. The same applies to glazing specification: a change from single to double glazing after manufacture begins is not a minor variation.
What a fabricator needs from you at the start of procurement: confirmed opening sizes with tolerances, the required design wind pressure or classification, the glazing specification including any safety or acoustic requirements, and any site access or installation constraints that affect frame depth or fixing method. In return, a competent manufacturer provides sample test reports, a factory QA summary, installation guidance aligned with NCC Part 8.2, and warranty conditions tied to correct installation. That exchange, done early, is what keeps a project on programme and on budget.
Hansaluminium: AS 2047-compliant aluminium windows for your project
Hansaluminium manufactures and supplies a full range of custom aluminium windows from its Sydney facility, covering fixed, sliding, awning, double hung, bi-fold and louvre configurations. Every product is manufactured to AS 2047:2014 with labelled units, test certificate support and factory quality assurance documentation ready for your compliance pack.

Where Hansaluminium adds direct value on compliance-sensitive projects is in the early engagement model: confirmed test reports matched to your specified sizes, installation guidance aligned with NCC Part 8.2, and project management from order through to sign-off. Browse the completed projects portfolio to see delivered work across residential, commercial and industrial builds, then contact the team for a quote matched to your drawings and required ratings.
Sources
- Part 8.2 Windows and external glazed doors | NCC
- Standards Catalogue | Standards Australia
- Compliance & Accreditation | AGWA