BASIX is the mandatory NSW sustainability certificate covering water, energy, and thermal performance for most development applications. NatHERS is the national thermal star rating system used across Australia to measure and model heating and cooling loads. NatHERS modelling routinely feeds into BASIX assessments, but it does not replace a BASIX certificate for any project inside NSW.
If you’re building, renovating, or extending in NSW, here’s what that means for your project:
- You’ll almost certainly need a BASIX certificate before lodging a development application or complying development certificate.
- If your design uses the simulation pathway rather than the DIY prescriptive route, you’ll need to engage a NatHERS accredited assessor early, before glazing and insulation decisions are locked in.
- Outside NSW, BASIX doesn’t apply at all. NatHERS assessments alone typically satisfy National Construction Code thermal requirements.
Key Takeaways
BASIX is the mandatory NSW compliance certificate, while NatHERS supplies the thermal modelling that commonly satisfies its energy and thermal component.
| Point | Details |
|---|---|
| BASIX is NSW-specific | A mandatory certificate covering water, energy, and thermal performance for most NSW developments. |
| NatHERS is national | A 1–10 star thermal rating system used across Australia to satisfy NCC energy requirements. |
| They’re not interchangeable | NatHERS modelling feeds the BASIX thermal pathway but can’t replace the BASIX certificate in NSW. |
| 2023 standards lifted the bar | BASIX thermal targets now align with roughly 7-star NatHERS equivalence in most zones. |
| Sequence your engagements | Lock glazing and insulation specs before generating your NatHERS or BASIX certificate to avoid rework. |
Table of Contents
- NatHERS vs BASIX: what BASIX actually covers in NSW
- What NatHERS actually measures and how ratings are produced
- When do you actually need BASIX or NatHERS?
- How NatHERS modelling actually feeds into a BASIX certificate
- BASIX vs NatHERS: the core differences at a glance
- What to budget for certificates and how long the process takes
- A practical checklist to get both right the first time
- Why your window and door choices decide the thermal outcome
- Get your glazing specification right before you lodge
- Why the industry keeps mixing these two up
- Sources
NatHERS vs BASIX: what BASIX actually covers in NSW
BASIX exists to answer one question for the NSW planning system: will this dwelling use less water and energy than a standard benchmark home? It does that across three performance pillars.
- Water score — measured against fixtures, landscaping, and any rainwater or greywater reuse.
- Energy score — covering hot water systems, lighting, and appliance energy use.
- Thermal performance — the heating and cooling loads a building is likely to need, driven by orientation, glazing, insulation, and construction materials.
BASIX certificates operate under the Sustainable Buildings SEPP, and NSW councils and accredited certifiers require a valid certificate as part of the development application or complying development certificate paperwork. Without one, most residential applications simply don’t proceed.
From 1 October 2023, BASIX raised its thermal and energy standards significantly, aligning most residential thermal targets with at least 7-star NatHERS equivalence and introducing a new materials index that accounts for embodied carbon in construction products. Some projects that lodged development applications before the changeover date qualify for transitional arrangements, so it’s worth checking lodgement dates carefully if your project has been sitting in planning limbo.

Homes meeting the updated 2023 standards are projected to save a substantial amount annually on energy bills compared to the previous benchmark, according to Planning NSW’s cost-benefit analysis. That figure is the trade-off regulators are banking on to justify higher upfront fabric costs, like better glazing and insulation.
You can meet the thermal requirement two ways: a DIY pathway using prescriptive checklists, or a simulation pathway using accredited NatHERS software. The BASIX assessment tool calculates your water and energy scores relative to a benchmark dwelling and reports your heating and cooling loads, so you can check which pathway suits your design before committing to a certificate.
What NatHERS actually measures and how ratings are produced
NatHERS is a national system, and it does one job well: it predicts how much energy a home’s fixed building fabric will need for heating and cooling. It doesn’t touch water use or appliance choices directly, though a newer companion metric does.
- The star rating runs from 1 to 10, and it reflects the home’s heating and cooling load based on climate zone, orientation, glazing, insulation, and construction type. A 6-star home needs noticeably less mechanical heating and cooling than a 3-star home in the same climate zone.
- The Whole of Home rating, scored from 0 to 100, expands the picture. It factors in fixed appliances, hot water systems, and any onsite solar or battery generation, giving a fuller energy performance picture than the star rating alone.
- Ratings are produced using NatHERS accredited software, with tools including AccuRate, BERS Pro, FirstRate5, and HERO. Each produces comparable results because they’re built to the same national protocol.
- Only a NatHERS accredited assessor can issue a certified rating. These assessors are trained and audited against the NatHERS assessor handbook, which sets out exactly how simulations must be run and documented.
- NatHERS ratings are the most common way builders satisfy National Construction Code energy efficiency requirements for new homes, but they’re also used voluntarily. Designers use them to test glazing options before committing to a build, and homeowners sometimes commission a rating on an existing home to understand where energy is leaking out.
Modern NatHERS certificates now include extra detail to match NCC 2022 changes, showing greenhouse gas emissions, the energy cost of major appliances, and the effect of solar panels or battery storage on the home’s overall performance.
When do you actually need BASIX or NatHERS?
The trigger points differ, and knowing which one applies to your project saves a lot of wasted paperwork.
BASIX is required in NSW when:
- You’re building a new dwelling of any kind, including granny flats and secondary dwellings.
- You’re renovating or extending an existing home where the works are valued at $50,000 or more.
- You’re installing a pool or spa holding 40,000 litres or more.
- Certificates must be lodged within the validity window tied to your development application; check current dates on the NSW Planning Portal since transitional rules shifted after the October 2023 changes.
NatHERS assessments are required or recommended when:
- Your project needs to demonstrate NCC energy compliance and you’re not using a deemed-to-satisfy prescriptive pathway.
- A designer or certifier requests thermal modelling to verify a glazing or insulation specification before construction.
- You want a voluntary rating on an existing home to guide a renovation or resale.
Outside NSW, there’s no BASIX equivalent. Most other states and territories rely on NatHERS ratings alone to satisfy NCC thermal requirements, which is one reason interstate builders sometimes get confused when a NSW project suddenly demands a BASIX certificate on top of the rating they already expected to need.
How NatHERS modelling actually feeds into a BASIX certificate
This is where most confusion sets in, and it’s worth being precise about it. BASIX is not a competitor to NatHERS. It’s a compliance gateway, and NatHERS modelling is one of the two ways to satisfy its thermal component.
- The DIY pathway uses a prescriptive checklist of construction elements, insulation values, and glazing specifications matched to your climate zone. It’s quick, but it’s inflexible. Some zones exclude dark roof colours entirely under this pathway because the model can’t account for the extra heat load a dark roof absorbs.
- The simulation pathway hands the job to an accredited NatHERS assessor, who models your actual design in software like AccuRate or FirstRate5 and produces heating and cooling load figures. Those figures feed directly into the BASIX thermal calculation, replacing the generic prescriptive checklist with numbers specific to your building.
- BASIX adopts NatHERS calculation methods for this pathway, but a NatHERS Whole of Home rating cannot be substituted directly for BASIX’s own energy standard. The two systems overlap in method, not in output. A separate BASIX energy score still needs to be generated even when NatHERS has done the thermal heavy lifting.
The practical upshot: if you want to keep a dark roof, a big bank of north-facing glass, or an unconventional floor plan, the simulation pathway usually preserves more design freedom than the DIY checklist. It costs more to run because you’re paying for an assessor’s time, but it lets a design team compensate for one weak spot, say, a large expanse of glazing, with a stronger performer elsewhere, like double-glazed frames with a lower U-value.
Pro Tip: Run your glazing and insulation choices through the BASIX sandbox or a NatHERS beta tool early in design. Beta tools can’t generate a final certificate, but they let you test options before locking in a spec that turns out to fail the real assessment.
Coordination between the NatHERS assessor, the building designer, and the certifier lodging the DA matters more than most project teams expect. A design that passes NatHERS modelling on paper can still stall at BASIX certification if the assessor’s assumptions about window schedules or appliance selections don’t match what actually gets built.
BASIX vs NatHERS: the core differences at a glance
Both systems assess thermal performance, but they exist for different reasons and produce different documents.
- Scope: BASIX covers water, energy, and thermal performance as a single NSW certificate. NatHERS focuses solely on thermal performance, expressed as a star rating, plus the broader Whole of Home energy picture.
- Output: BASIX issues a regulatory certificate with a unique number that councils and certifiers check against your DA. NatHERS produces a scientific rating certificate and assessor report, without regulatory authority on its own outside the NCC pathway.
- Legal role: BASIX is the compliance gateway for residential development in NSW. Without it, your DA doesn’t get assessed. NatHERS supplies the accredited modelling that satisfies the thermal component of that gateway, or independently satisfies NCC requirements in states without BASIX.
- Who issues it: BASIX certificates are generated through the online BASIX tool once the assessment is complete. NatHERS ratings can only be issued by an accredited assessor using approved software.
- What’s recorded: A BASIX certificate records water, energy, and thermal commitments the builder must meet on-site. A NatHERS certificate records the star rating, Whole of Home score, and the specific building fabric assumptions the rating relied on.
Think of NatHERS as the engineering behind the number, and BASIX as the legal document that says the number is good enough for NSW.
What to budget for certificates and how long the process takes
NatHERS assessments typically run from a few hundred dollars for a straightforward new home design up to more for complex or architecturally unusual builds, with cost driven mainly by design complexity, floor area, and how many iterations the assessor needs to run. BASIX certificates carry their own separate cost, generally more modest, since much of the assessment happens through the online tool once your NatHERS inputs (if used) are ready.
- BASIX certificates are tied to development application lodgement, and most councils expect the certificate to remain current through the assessment period. A three-month validity window is a common practical rule of thumb for lodgement, so don’t generate your certificate too far ahead of submitting your DA.
- NatHERS assessor turnaround is often one to two weeks depending on design complexity and how quickly you supply plans.
- BASIX certificate generation itself is usually fast once inputs are finalised, often same-day through the portal.
- Sequence matters: finalise your NatHERS inputs before generating the BASIX certificate, not after, to avoid paying for two rounds of assessment.
A practical checklist to get both right the first time
Getting BASIX and NatHERS aligned early saves weeks of rework later. Follow this sequence.
- Prepare complete plans showing orientation, glazing schedule, wall and roof construction, and shading elements.
- Choose your BASIX pathway — DIY prescriptive or simulation — based on how much design flexibility you need.
- Engage a NatHERS accredited assessor if you’re using the simulation pathway, well before construction drawings are finalised.
- Reconcile the assessor’s modelling outputs with the BASIX tool to confirm your thermal, water, and energy scores all clear the required thresholds.
- Generate your BASIX certificate through the online portal once every input is locked.
- Lodge the certificate with your development application or complying development certificate.
An assessor needs accurate orientation data, a full glazing schedule (frame type, glass specification, sizes), construction material details for walls and roof, and your chosen appliance and hot water system before they can model anything meaningfully. The design levers with the biggest thermal impact are glazing specification, frame thermal breaks, insulation levels, roof colour, and shading design.
Pro Tip: Lock your glazing and insulation specification before generating your NatHERS certificate. Changing window sizes or frame types afterwards means re-running the assessment, and that delay lands right when your DA clock is ticking.
Why your window and door choices decide the thermal outcome
Glazing area, frame thermal performance, and the solar heat gain coefficient (SHGC) of your windows and doors are among the biggest levers in any NatHERS model. A large expanse of poorly performing glass drags down a star rating fast, while a well-specified frame with a low U-value can claw back thermal performance elsewhere in the design.
- Thermally broken aluminium frames reduce heat transfer through the frame itself, not just the glass.
- The right SHGC for your climate zone and orientation cuts cooling loads in summer without sacrificing winter light.
- Door selection matters too. Large sliding or stacking doors introduce significant glazed area and need the same scrutiny as windows.
Hans Aluminium manufactures its window ranges in Australia specifically for the thermal demands NatHERS modelling throws up, and the team supports designers through specification so glazing choices meet BASIX thermal targets without unnecessary compromise.
Get your glazing specification right before you lodge
Choosing the right windows and doors early avoids the compensating-measures scramble that happens when a NatHERS model comes back short. Hans Aluminium’s project portfolio shows how thermally efficient glazing and door systems have helped NSW builds meet both BASIX and NatHERS targets without redesigning floor plans late in the process. Whether you’re speccing large openings with bi-fold windows or need shading and ventilation control through awning windows, getting the frame and glass specification right the first time keeps your certificate process moving instead of stalling on a failed thermal score.

Why the industry keeps mixing these two up
The biggest misconception in this whole space is treating BASIX and NatHERS as rival standards, as if you’d pick one over the other. You wouldn’t, and you can’t. BASIX is the legal gateway; NatHERS is the engineering behind one part of it. Conflating the two is why so many project teams get blindsided late in the design process, usually when a certifier flags a mismatch between what the NatHERS assessor modelled and what actually made it onto the construction drawings.
Where conventional advice falls short is in treating thermal compliance as a checkbox exercise handled entirely by the assessor. It isn’t. The building fabric decisions, particularly glazing area, frame performance, and door selection, are made by designers and builders long before an assessor ever opens their modelling software. By the time a NatHERS rating comes back short, changing the glazing spec is expensive and slow.
If you take one thing from this: get your window and door specification locked with performance figures in hand before your assessor starts modelling, not after. That single sequencing fix prevents more approval delays than any other step in this process.
— Hans
Sources
- Residential building sustainability (BASIX) – Planning Portal
- Sustainability standards for residential development — Planning NSW