SHGC, or Solar Heat Gain Coefficient, measures the fraction of solar radiation that passes through a window assembly as heat, on a scale from 0 to 1. The lower the number, the less solar heat enters your home. For most Australian climates, that means choosing SHGC below 0.30 for cooling-dominated regions, while north-facing glazing in cooler southern states can benefit from a moderate SHGC in the 0.30–0.60 range to capture passive solar warmth in winter.
A few things to know before you go further:
- SHGC controls solar heat. It measures how much of the sun’s energy enters as heat, regardless of whether the window is open or closed.
- U-value controls conductive heat flow. It measures how well the window resists heat transfer from temperature differences alone, independent of sunlight. Both metrics matter; neither replaces the other.
- Australian labelling uses whole-window values (SHGCw). The Window Energy Rating Scheme (WERS) and NatHERS provide the certified ratings you need for compliance and genuine performance comparisons.
- YourHome (the Australian Government’s housing design guide) is the go-to reference for climate-specific glazing recommendations.
- Hansaluminium designs and supplies custom aluminium windows with glazing specifications matched to your climate zone and orientation, so you get the right SHGC built into the assembly from the start.
Table of Contents
- What does SHGC actually measure?
- How does SHGC differ from U-value, and which should you prioritise?
- How to read Australian window energy labels
- What SHGC ranges should you expect from different glazing types?
- Choosing SHGC by Australian climate zone and window orientation
- How to balance daylight and heat using VT and the LSG ratio
- How SHGC choices affect your energy bills and comfort
- Your supplier checklist before you buy or install
- Key takeaways
- A manufacturer’s perspective on getting SHGC right
- Hansaluminium can help you specify the right glazing
- Useful sources and further reading
What does SHGC actually measure?
SHGC stands for Solar Heat Gain Coefficient, and it quantifies the fraction of incident solar radiation admitted through a window as heat. A window rated at 0.27 admits 27% of the solar energy striking it; one rated at 0.50 admits 50%. The scale runs from 0 (no solar heat admitted) to 1 (all solar heat admitted), though real products sit between roughly 0.15 and 0.87.
The number covers the whole window assembly: glazing, frame, spacers, and any dividers. That is an important distinction. Centre-of-glass SHGC, sometimes quoted in brochures, only measures the glass pane itself and will almost always look better than the whole-window figure. Frames, spacers, and divided lites all alter the measured result, so a bare-glass number is not a reliable basis for comparing products or meeting energy codes.
SHGC replaced the older Shading Coefficient (SC) metric. SC was measured at a single wavelength and applied only to the glass, making it a poor predictor of real-world performance. SHGC uses a wavelength-by-wavelength integration across the full solar spectrum and accounts for the entire assembly, which is why it is now the standard in Australia and internationally.
To put the numbers in context: a living room in coastal Queensland with a 0.50-rated west-facing window will absorb substantially more afternoon heat than the same room fitted with a 0.27-rated spectrally selective unit. In a Victorian home relying on north-facing passive solar in winter, a 0.50 SHGC on that north wall can meaningfully reduce heating demand, while the same rating on an east or west window would create overheating problems in summer.
How does SHGC differ from U-value, and which should you prioritise?
These two metrics measure completely different things, and confusing them is one of the most common specification mistakes in Australian residential construction.
U-value (or U-factor) measures non-solar conductive heat flow: how readily the window transfers heat between inside and outside due to temperature differences, with no sun involved. A lower U-value means better insulation. SHGC measures solar heat admitted when sunlight strikes the glass. A lower SHGC means less solar heat entering the building.

Like SHGC, U-value should be quoted for the whole window (Uw), not just the centre of glass (Ug). Aluminium frames conduct heat readily, so in temperate Australian climates, frames with thermal breaks are needed to achieve a Uw that genuinely performs.
When to prioritise each:
| Climate type | Primary priority | Secondary priority | Reason |
|---|---|---|---|
| Cooling-led (tropical, subtropical QLD/NT/WA) | Low SHGC (<0.30) | Moderate Uw | Solar heat drives cooling loads; conductive loss is less critical |
| Heating-led (alpine, southern VIC/TAS) | Low Uw | Moderate-to-high SHGC (north-facing) | Conductive heat loss dominates; north-facing solar gain is an asset |
| Mixed climate (coastal NSW, ACT, SA) | Balance both | SHGC by orientation | Neither solar nor conductive heat dominates year-round |
Specifying an extremely low SHGC in a cool climate can actually increase heating costs by blocking winter solar gain that would otherwise offset your heating load. The reverse is equally true: a high SHGC in a hot climate pushes cooling demand up sharply. High-performance builds target both metrics together rather than optimising one in isolation.

Pro Tip: In mixed climates, specify SHGC by orientation rather than applying one value across the whole building. North-facing glazing can carry a higher SHGC than east, west, or south-facing windows in the same project.
How to read Australian window energy labels
Australia uses two main frameworks for window energy performance: WERS and NatHERS.
WERS (Window Energy Rating Scheme) is administered under the NatHERS umbrella and provides star ratings for windows based on their heating and cooling performance in specific Australian climate zones. A WERS label shows the whole-window SHGC (SHGCw), visible transmittance (VT), and U-value (Uw), along with air leakage data. These are the numbers to use for compliance and genuine product comparisons.
NatHERS (Nationwide House Energy Rating Scheme) is the broader residential energy rating framework. Window performance data fed into NatHERS software tools (such as AccuRate and FirstRate5) must use whole-window certified values, not centre-of-glass figures from a brochure.
When reading a product data sheet or label, look for:
- Air leakage rating — relevant for airtight, energy-efficient builds
A common pitfall: manufacturers sometimes lead with centre-of-glass SHGC in marketing materials because it looks more favourable. Always ask for the SHGCw on the certified data sheet, and cross-reference it against the WERS product directory if you want independent confirmation.
Pro Tip: Some operable windows (awnings, louvres) can be rated in both open and closed states, giving two SHGC values on the technical data. The closed-state SHGCw is the one used for energy compliance calculations.
What SHGC ranges should you expect from different glazing types?
Glazing construction, coatings, and the number of panes all shift SHGC and VT significantly. The table below shows typical whole-window ranges you will encounter in Australian product specifications.
| Glazing type | Typical SHGCw | Typical VT | Notes |
|---|---|---|---|
| Single glazed (clear) | 0.87 | 0.87 | Minimal solar control; rarely suitable for new builds |
| Double glazed (clear) | 0.55 | 0.65 | Better insulation; limited solar control |
| Double glazed with Low-E | 0.31–0.40 | 0.40–0.51 | Wide range depending on coating type and position; spectrally selective double glazing (Low-E) achieves SHGC ≈ 0.31, VT ≈ 0.51 |
| Tinted glazing | 0.50 | 0.35 | Reduces both heat and daylight; can feel dark indoors |
| Spectrally selective Low-E | 0.31 | 0.51 | High LSG; best daylight-to-heat ratio |
| Triple glazed with Low-E | 0.37 | 0.48 | Excellent Uw; diminishing SHGC returns vs double + selective Low-E |
Spectrally selective coatings work by blocking near-infrared radiation (heat) while allowing visible light to pass through. This decouples daylight from heat gain, which is why spectrally selective double glazing can achieve a much higher LSG than standard double glazing or tinted glass. A spectrally selective unit can show SHGC ≈ 0.31 and VT ≈ 0.51, while a tinted unit achieving the same SHGC might only deliver VT ≈ 0.35, leaving interiors noticeably darker. Typical triple-glazed Low-E units show SHGC ≈ 0.37 and VT ≈ 0.48.
Frame material matters too. Aluminium frames have higher thermal conductivity than timber or uPVC, which lowers the whole-window SHGC compared with the centre-of-glass figure. Thermal breaks in aluminium frames reduce this effect and are standard practice in quality Australian aluminium window systems.
In most Australian climates, pairing high-quality double glazing with a selective Low-E coating delivers better cost-to-performance outcomes than moving to triple glazing. Triple glazing adds weight, cost, and complexity without proportionally improving SHGC control once you already have a well-specified Low-E unit.
Pro Tip: Ask your glazing supplier for the specific Low-E coating position (surface 2 or surface 3 in a double-glazed unit) and its spectral properties. The coating position affects both SHGC and Uw, and not all Low-E coatings perform the same way.
Choosing SHGC by Australian climate zone and window orientation
There is no single correct SHGC value for every window. The right choice depends on where you are building and which direction the window faces.
Climate rules of thumb:
- Cooling-dominated climates (tropical north QLD, Darwin, inland WA): target SHGCw below 0.27 on all orientations. Solar heat is the dominant load year-round, and even modest gains add up quickly.
- Mixed climates (coastal NSW, Adelaide, Perth): target SHGCw below 0.30 for east and west glazing; north-facing glazing can sit at 0.30–0.40 with appropriate external shading.
- Heating-dominated climates (alpine VIC, Tasmania, ACT highlands): prioritise low Uw first; north-facing glazing at 0.40–0.60 captures passive solar warmth that reduces heating demand.
Orientation-specific guidance:
- North-facing (southern hemisphere): This is where passive solar design pays off. Moderate-to-higher SHGC (0.30–0.50) combined with a well-designed eave or external awning lets winter sun in while blocking the high summer sun. The shading does the seasonal work; the glazing captures the gain.
- West-facing: Afternoon sun is low in the sky and intense. Low SHGC (below 0.27) is the priority here. Even with external shading, west-facing glazing in Queensland or NSW can drive significant cooling loads if SHGC is not controlled.
- East-facing: Morning sun is less intense than afternoon west sun, but still warrants low SHGC (below 0.30) in warm climates. In cooler climates, east glazing with moderate SHGC can contribute morning warmth without the overheating risk of west glazing.
- South-facing: Receives little direct sun in Australia. SHGC is less critical here; focus on low Uw to minimise conductive heat loss. Higher VT is useful for daylight without the solar heat penalty.
Three practical scenarios:
A coastal NSW home (mixed climate) benefits from SHGCw ≈ 0.30–0.35 on north-facing living areas with a 600mm eave, SHGCw below 0.27 on west-facing bedrooms, and a low Uw across all orientations for overnight comfort.
A Victorian home in a heating-dominated zone should specify SHGCw ≈ 0.40–0.50 on north-facing glazing to maximise winter solar gain, paired with Uw below 2.0 W/m²K to hold that heat overnight.
An inland Queensland home (cooling-dominated) needs SHGCw below 0.27 on every orientation, with external shading on north and west elevations as a second line of defence.
Combining external shading with low SHGC glazing reduces peak cooling loads more effectively than either measure alone. Awnings, pergolas, and deciduous trees on north and west elevations work with the glazing specification rather than substituting for it.
How to balance daylight and heat using VT and the LSG ratio
Visible Transmittance (VT) measures the fraction of visible light that passes through the window assembly, on the same 0–1 scale as SHGC. A window with VT of 0.51 transmits 51% of visible light.
The Light-to-Solar Gain ratio (LSG) is calculated as:
LSG = VT ÷ SHGC
A higher LSG means more daylight for every unit of solar heat admitted. This is the key metric for choosing glazing that keeps interiors bright without overheating.
Worked example:
Suppose you are comparing two double-glazed units for a west-facing study in Sydney:
- Unit A (tinted): VT = 0.35, SHGC = 0.30 → LSG = 0.35 ÷ 0.30 = 1.17
- Unit B (spectrally selective Low-E): VT = 0.51, SHGC = 0.31 → LSG = 0.51 ÷ 0.31 = 1.65
Both units achieve a similar SHGC, so their solar heat control is comparable. But Unit B delivers 46% more daylight per unit of heat admitted. The study stays brighter without extra cooling load.
As a general guide: LSG above 1.25 indicates good spectral selectivity. LSG below 1.0 means the glazing blocks more light than heat, which usually points to a heavy tint or an older coating technology.
Pro Tip: Spectrally selective Low-E coatings are the most reliable way to achieve LSG above 1.25 while keeping SHGC below 0.35. If a product claims both low SHGC and high VT without a selective coating, ask for the independent test data.
How SHGC choices affect your energy bills and comfort
The relationship between SHGC and energy costs is direct but not always obvious in both directions.
In warm months, a high SHGC on west or east-facing glazing increases the cooling load your air conditioning must handle. Afternoon overheating from unshaded west-facing windows is one of the most common comfort complaints in Australian homes, and it is almost always a glazing specification problem. Reducing SHGCw from 0.60 to 0.27 on a large west-facing window can meaningfully cut peak cooling demand, though the exact saving depends on window area, climate zone, and shading.
In cooler months, the picture reverses for north-facing glazing. A higher SHGC on a north-facing window in Victoria or Tasmania admits solar warmth that offsets heating demand during the day. The trade-off is that the same glazing offers less resistance to radiant heat loss at night, which is why pairing a moderate SHGC with a low Uw on north-facing glazing is the standard recommendation for mixed and heating-dominated climates.
Key practical impacts to keep in mind:
- Overheating risk — from high SHGC on west-facing glazing is often felt as discomfort before it shows up on an energy bill. Occupants close blinds, which blocks daylight and reduces the benefit of having windows at all.
When the glazing area is large or the climate is extreme, energy modelling through NatHERS-accredited software gives a quantified picture of the heating and cooling load impact before you commit to a specification.
Your supplier checklist before you buy or install
Use this checklist when reviewing quotes, technical data sheets, and at handover. It covers the questions that catch the most common specification and performance mistakes.
On the technical data sheet:
- SHGCw (whole-window, not centre-of-glass) is stated and matches the WERS-certified value
- VT (visible transmittance) is listed for the whole window assembly
- Uw (whole-window U-value) is confirmed, not just Ug (centre-of-glass)
- Air leakage rating is provided
- WERS certification number is present and can be verified in the WERS product directory
Questions to ask your supplier:
- What is the Low-E coating specification, and on which glass surface is it applied?
- Does the frame include a thermal break, and what is its thermal performance?
- What spacer type is used in the insulated glazing unit (warm-edge vs aluminium)?
- What is the installed SHGCw for the complete assembly, including frame and any dividers?
- What warranty applies to the glazing unit and the coating?
- How should coated glass be cleaned to preserve coating performance?
Design and orientation checks:
- Has SHGC been specified per orientation (not one value for the whole building)?
- Are external shading measures (awnings, eaves, screens) designed to complement the SHGC choice?
- For awning windows or louvres, has the open-state performance been considered for natural ventilation?
- Is thermal mass present to store solar gain from north-facing glazing?
At handover:
- Installed product labels match the specified SHGCw and Uw on the data sheet
- WERS or NatHERS documentation is supplied with the handover pack
- Any site-applied film or screen is accounted for in the final performance figures
Key takeaways
Choosing the right SHGC for your windows requires matching the whole-window SHGCw to your climate zone and orientation, not applying a single value across the entire building.
| Point | Details |
|---|---|
| SHGC measures solar heat admitted | The 0–1 scale tells you the fraction of solar energy entering as heat; lower means less solar heat. |
| Climate and orientation drive the choice | Cooling-dominated climates generally require low SHGCw for solar heat control; north-facing glazing in cooler zones can use moderate SHGCw to capture passive solar warmth. |
| Always specify whole-window SHGCw | Centre-of-glass figures in brochures are not comparable to WERS-certified whole-window values. |
| Balance VT and SHGC using LSG | LSG = VT ÷ SHGC; target above 1.25 with spectrally selective Low-E to keep interiors bright without excess heat. |
| Hansaluminium for custom specification | Hansaluminium designs and supplies custom aluminium windows with glazing matched to your climate zone and orientation. |
A manufacturer’s perspective on getting SHGC right
Most glazing conversations in residential construction start with aesthetics and end with price. SHGC gets added to the brief late, often as a compliance checkbox rather than a design input. That ordering is backwards, and it costs homeowners real money in energy bills and comfort.
At Hansaluminium, the glazing specification conversation happens at the design stage, not after the window schedule is locked. The reason is straightforward: once you have committed to a frame profile, sash configuration, and opening type, your options for adjusting SHGCw narrow considerably. A fixed window and a double hung window in the same opening will have different whole-window SHGCw values even with identical glazing, because the frame-to-glass ratio differs. Getting that right requires knowing the orientation and climate zone before the window schedule is drawn.
The other thing worth saying plainly: low SHGC is not always better. Specifying the lowest available SHGC across every orientation in a Melbourne renovation is a mistake that will show up as higher heating bills and cold, underlit interiors in winter. The right specification is orientation-specific, climate-informed, and balanced against U-value. That is the kind of advice Hansaluminium brings to every project, backed by Australian-made manufacture and hands-on project management from design through to installation.
Hansaluminium can help you specify the right glazing
Getting SHGC right from the start saves money on energy costs and avoids the discomfort of retrofitting shading or film after installation. Hansaluminium supplies custom aluminium windows with glazing specified to your climate zone, orientation, and NatHERS compliance requirements, all manufactured in Australia with full project management support.

Whether you are a builder working through a window schedule or a homeowner planning a renovation, the team at Hansaluminium reviews your design, advises on SHGCw and Uw targets by orientation, and supplies certified products with full WERS documentation. See the completed projects for real-world examples of glazing choices in Australian homes, or browse the full window range to start matching products to your specification. Contact Hansaluminium for a design review and quote tailored to your project.
Useful sources and further reading
These are the authoritative Australian and international references used throughout this article. Each is worth bookmarking if you are specifying windows for a new build or renovation.
- YourHome — Glazing: — The Australian Government’s housing design guide covers climate-specific glazing recommendations, orientation strategies, and shading design. The most practical starting point for Australian homeowners and builders.
- Australian Government — Energy Rating: Covers appliance and building energy rating programmes in Australia, including links to relevant standards and compliance pathways.